Easy handling and high quality on thin sheet: this is what makes the tip ignition (CD) processes so convincing. Here you will find the strengths, typical applications and variants of the process as well as the technical data.
In short
In tip ignition, the arc forms via the ignition tip of the stud with a very high current and within a few milliseconds. The process is suitable for studs from 0.8 to 8 mm on sheet from 0.5 mm, and the units run on a standard 230 V socket. There are two variants: the contact method and the gap method.
On this page
What are the advantages of tip ignition?
- low-cost weld studs
- a standard 230 V AC socket is sufficient
- easy handling
- low-cost units
- easy to automate
- no marks or, depending on the application, only faint marks on the reverse side
- painted reverse sides possible
Where is tip ignition used?
Typical applications are control cabinet construction, vehicle construction, façade technology, cathodic corrosion protection and insulation on metal.
What variants of tip ignition are there?
The tip ignition process is divided into the contact method and the gap method. On the following pages, both methods are explained in more detail, with application strengths and technical details.
The stud rests on the sheet with its ignition tip before welding. Strong for manual welding of steel and on galvanised and slightly curved surfaces.
The stud is held at a small distance and only placed on the sheet during welding. Strong on aluminium, on thin sheet with high requirements for the back and in automated welding.
Where are the process limits?
The basic rule also applies to stud welding: the joint must not fail in the fusion zone. During the extremely short welding time, the entire surface of the weld stud and the workpiece must be melted. This results in process limits beyond which compromises in strength must be accepted.
The following table shows dimensions with which process-reliable joints according to DVS can be achieved. Other dimensions can in some cases be welded well and reliably, but should be checked by tests on the actual welding task. A welding procedure test according to DIN EN ISO 14555 can usually only be passed with considerable effort.
What technical data apply?
| Parameter | Gap welding | Contact welding |
|---|---|---|
| Process no. according to ISO 4063 | 786 | 786 |
| Stud diameter d (mm) | 0.8 to 8 (aluminium up to 6) | 0.8 to 8 (aluminium up to 6) |
| Peak current approx. (A) | 10,000 | 10,000 |
| Welding time approx. (ms) | 0.5-2 | 1-4 |
| Spring force approx. (N) | 40-60 | 60-100 (depending on piston dimensions and bearing) |
| Impact speed approx. (m/s) | 0.5-1 (aluminium 1-1.5) | 0.5-0.7 |
| Ignition | Mostly correct (early ignition possible), high process reliability |
Always correct, high process reliability |
| Barely visible marks on the back | yes | yes |
| Material | St, VA, MS, AL (and others) |
St, VA, MS, AL (and others) |
| Min. workpiece thickness (mm) | 0.5 | 0.5 |
| Insulation applications | yes | yes |
| Application strengths |
|
|
| Use outside the process limits | ||
| Geometric limit |
|
|
| Limit of weldability of the workpiece material |
|
|
| Values may vary depending on unit and application | ||
The values in the table above are based on Table 1 of DVS 0903:2018.
Would you like to know whether tip ignition suits your component?
We will be happy to advise you personally, by phone on +49 2302 95640-0 or by message.